DT Receiver - Rx43d-3 - v520 Instructions
|
|
|
|
|
1. DEFAULT SETUP
- Tank with 2 motor steering (reversable), Turret motor (reversable), Canon elevation (servo) and 3-6 Lights.
- Train with 1 motor (reversable) and 3-5 Lights (requires H3 channel to be changed to Ch3).
- Car with 1 motor (reversable) and 3-5 Lights (requires H3 channel to be changed to Ch3).
- Plane requires more changes.
- All outputs can be customised / re-configured.
Output | Type | Channel | Other |
H1: | Motor 1 with steering mix (center off) | Ch3 Drive/Ch2 Steer | 25% steering mix |
H2: | Motor 2 with steering mix (center off) | Ch3 Drive/Ch2 Steer | Not reversed |
H3: | Motor 3 (center off) | Ch4 | Turret, Train or Car motor |
F1: | Switch (eg: light, radar dish, etc) | Ch6 | |
F2: | Switch (eg: light, pump, etc.) | Ch7 | |
P1: | Servo | Ch1 | Canon elevation, Car steering. etc. |
P2: | Driving lights Leds (Front & Rear) | Ch5 | |
P3: | Brake Led | Ch3 auto activate | |
P4: | Reverse Led | Ch3 auto activate | |
Arming/Activation: | Mid-stick to enable | Ch3 | |
LVC |
Mid-stick to acknowledge Brake light ON; outputs OFF 5-flash |
Ch3 | |
LED2 | External LED to show receiver activity | P2 (driving lights) |
2. EXAMPLE CONNECTIONS:
|
|
for extra H output |
|
|
|
|
|
LEDs with 1S Lipo:
Led's driven from P outputs only require a current limiting resistor (8mA max).
Led's driven from F outputs only require a current limiting resistor (2A max).
LEDs with 5-6v:
'P' outputs are 3v when 'off' and 0v when 'on'. So when used with higher voltages, the leds driven from P outputs also need diodes to reduce the voltage. This is because 5 or 6v is high enough above the 3v output to make Leds conduct even when P outputs are 'off'. An example is shown in the Led (P1) diagram.
Led's driven from F outputs only require a current limiting resistor when operated off any voltage up to 6v.
GRAIN of WHEAT:
Grain of Wheat bulbs usually draw >8mA so are not suitable for use with P outputs (unless buffered with a transistor).
Grain of Wheat bulbs can be driven from F outputs. F outputs allow the intensity to be varied with stick movement or 'Travel Adjust'.
3. CHANGING OUTPUTS:
All outputs can be customised / re-configured:
PROGRAMMING
4. GENERAL:
The Rx is not insulated.
The PCB is thin so do not bend it.
5. LED:
Led On = perfect reception (real-time indicator).
1 flash = Scanning (~2sec between flashes; wrong model if never stops).
2 flash = Selecta (model not active).
5 flash = Brownout (receiver voltage went too low; check battery/servo load).
6. FAILSAFE:
Outputs are not driven (do nothing) on startup and while scanning.
Outputs 'hold' on short signal losses (<3sec) and then do nothing (>3s).
7. BINDING:
1. Switch Rx on and wait ~20s until led flickers fast.
2. Switch Tx on in bind mode and Rx led should flash slowly and then go solid.
3. Change distance between Tx/Rx if binding does not work.